Liebert CRV, Row-based Cooling Unit

Liebert CRV, Row-based Cooling Unit

Liebert CRV, Row-based Cooling Unit

In Stock

A self-contained data center cooling unit that is ideally suited and designed for cooling server rack cabinets in small and medium data centers. Liebert CRV features Vertiv ICOM Control and compressor with modulating capacity, for high reliability and optimized data center heat management.​​​​​

  • Description
  • Technical Specifications

Liebert CRV uses environmentally-friendly R410A refrigerant, and is available in different versions, depending on data center design requirements: • 10 and 20 kW Direct Expansion (DX) air cooled version, available in the 300 mm frame • 23 and 36 kW Direct Expansion (DX) air/water cooled version, available in the 600 mm frame • 39 to 57 kW Chilled Water (CW) cooled systems, available in the 300 mm frame • 46 and 58 kW Chilled Water (CW) cooled systems, available in the 600 mm frame • 50 or 60 Hz models

  • Horizontal airflow cooling design is suitable for non-raised or raised floors
  • Air, water, glycol and chilled water systems available
  • Adjustable airflow baffles maximize cooling to rack equipment, allowing the system to be positioned within the row or at the end of the row
  • Multiple units communicate with each other to improve system performance and reduce energy consumption
  • Up to 10 racks per cooling unit may be monitored to improve system performance and report rack temperatures
  • Vertiv ICOM graphic display allows easy navigation and clear data display
  • Self-adapts to changing conditions to provide 24/7 precision environmental control: cooling, humidity control and air filtration
  • Vertiv ICOMTM Control provides alerts for preventive maintenance before issues occur
  • Variable capacity compressor adapts to load and eliminates compressor cycling, greatly increasing compressor life-time.
  • Designed for higher return air temperature to maximize cooling capacity
  • Only front and back access required, resulting in minimized installation and service time
  • Variable capacity compressor and variable speed EC fans operate efficiently to reduce energy consumption
  • Small to medium-sized data centers cold/hot aisle configurations
  • Heat density up to 10 kW/rack without containment
  • Raised and non-raised floors
  • Rooms with a low ceiling where air cannot be ducted
    Spot cooling in large data centers
  • Features variable speed EC plug fans and variable capacity compressor
  • Enlarged range available from 10 to 60 kW
  • Efficient operation with Vertiv ICOMTM Control. The graphic display allows easy navigation and clear data display
  • Includes a 300 mm space saving frame
  • Thermal management and humidity control
  • Installs within the row of racks
  • Low energy consumption